當前位置:工程項目OA系統(tǒng) > 建筑OA系統(tǒng) > 工程管理軟件
SBR工藝中短程硝化反硝化的過程控制
簡介: 實驗室中通過DO、pH值、進水CODcr /NH3-N(C/N)等參數(shù)的控制實現(xiàn)了SBR工藝中的短程硝化反硝化。在以人工玉米水為外加碳源、進水氨氮濃度100mg/L、CODcr=800mg/L的條件下,保持pH 8.0~8.2、DO 0.5 mg/L~1.0mg/L,通過對反應周期10小時內(nèi)氨氮(NH3-N),亞硝基氮(NO2--N),硝基氮(NO3--N)的跟蹤以及對反應周期內(nèi)每小時間隔們內(nèi)這些氮的不同形態(tài)的變化量的數(shù)據(jù)的分析,證實在整個系統(tǒng)內(nèi)短程硝化反硝化是占主導地位的脫氮途徑。
關鍵字:SBR 短程硝化反硝化 工藝參數(shù)
Process control of Shortcut nitrification—denitrifiction in SBR process
Pandeng, Liujun, Wangbin, Wangping (School of Chemical and Environmental Engineering, Beijing Technology and Business University,Beijing 100037)
Abstrate: Shortcut nitrification—denitrifiction was achieved in SBR through the control of technologies’ operation parameters such as DO、pH、C/N and so on.The experiment result show that When burthen of ammonia nitrogen is 100mg/L, C/N=8, pH 8.0~8.2、DO 0.5 mg/L~1.0mg/L, we can conform that Shortcut nitrification—denitrifyction is dominating approach of the removal of ammonia nitrogen by tracing ammonia nitrogen,nitrite and nitrate.
Key words: SBR, Shortcut nitrification—denitrifyction, technology parameters
與傳統(tǒng)的生物脫氮相比,亞硝酸型生物脫氮具有節(jié)約能耗,減少外加碳源,提高反應速率,節(jié)省基建投資,減少污泥量等特點[1]。硝化過程是由兩類自養(yǎng)型硝化細菌完成的,將NH3-N轉(zhuǎn)化為NO2--N的一類菌被稱為Nitrosomonas,將NO2--N轉(zhuǎn)化為NO3--N的被稱為Nitrobacter[2],實際上這兩類菌的微生物學特征存在一定的差距,這為SBR中通過過程控制實現(xiàn)淘汰硝化菌,將硝化控制在NO2--N的階段提供了可能性。
1.實驗裝置與方法
實驗室有大、小兩套SBR裝置。小反應器有效容積0.8L,用來對pH值、DO等控制參數(shù)進行對比實驗,摸索有利于實現(xiàn)短程硝化反硝化的條件。然后按照選出的最佳條件在有效容積12L的大反應器中對一個周期內(nèi)的NH3-N、NO2--N以及NO3--N進行以小時為單位的跟蹤,以驗證實驗結(jié)果。首先在12L的大反應器中對污泥進行馴化,參照SHARON、ANAMMOX等一些工藝的運行條件[3][4][5][6],馴化期間進水NH3-N100mg/L;COD400mg/L,pH始終維持在7.5~8.5,DO維持2mg/L左右;1個月后測定中間時刻5hr和出水水質(zhì)指標,發(fā)現(xiàn)了運行周期內(nèi)有明顯的NO2--N積累,TN和COD去除率分別達到60%~70%和80%以上。以相近的污泥濃度(12L的大反應器中污泥濃度3.2g/L~3.5g/L)取適量污泥在小反應器內(nèi)進行實驗。每個周期內(nèi)小反應器排水0.4L進水0.4L,大反應器排水6L進水6L,所有實驗均在20~25℃內(nèi)進行。實驗室以有機氮水自配,[NH3-N]=11000mg/L,作為外加碳源的玉米水COD=26000mg/L,BOD/COD=0.6,各項水質(zhì)分析指標均按照標準方法進行。
2.實驗結(jié)果
2.1 小反應器實驗結(jié)果
2.1.1 DO的影響
進水NH3-N100mg/L;COD400mg/L;pH始終維持在7.5~8.5,出水數(shù)據(jù)見表1。可以看出:在較低DO條件下,有利于NO2--N的積累,DO過高容易將NO2--N氧化成NO3--N;而且過高的DO將會加速有機碳源的氧化速率,使后半程的反硝化反應得不到充足的碳源,阻礙反硝化反應的進行;但如果DO過低,硝化反應不完全,1#出水ηTN過低,僅為53.5%。綜合DO對ηTN和NO2--N的積累考慮,選定DO維持在0.5mg/L~1.0mg/L。
表1 不同DO下出水水質(zhì)
編號DO(mg/L)NH3-N(mg/L)NO2--N (mg/L)NO3--N (mg/L)ηTN(%)ηCOD(%)NO2--N/NO3--N1#0.2左右37.416.60.553.561.533.22#0.5~1.00.734.00.964.376.537.83#1.0~2.0023.65.271.286.24.52.1.2 pH的影響
進水條件依然保持NH3-N100mg/L;COD400mg/L;DO維持0.5~1.0mg/L;pH分別維持在7.5~7.8,7.8~8.0,8.0~8.2,8.2~8.5,出水數(shù)據(jù)見表2。實驗過程中pH用固體Na2CO3和5%的硫酸調(diào)節(jié)。可以看出:pH維持在7.5~7.8時1#出水ηTN過低,僅為45.6%,綜合pH對ηTN和NO2--N的積累考慮,選定pH維持在8.0~8.2。
表2 不同pH下出水水質(zhì)
編號pHNH3-N(mg/L)NO2--N (mg/L)NO3--N (mg/L)ηTN(%)NO2--N/NO3--N1#7.5~7.8024.030.445.60.82#7.8~8.0021.95.172.74.33#8.0~8.2022.63.673.26.34#8.2~8.5018.215.766.11.22.1.3不同C/N的影響
進水條件依然保持NH3-N100mg/L,DO維持0.5~1.0mg/L,pH維持8.0~8.2,按進水COD分別為200mg/L,400mg/L,800mg/L(C/N=2,4,8)運行,出水數(shù)據(jù)見表3。1#出水NO2--N的積累較2#和3#差,說明C/N小于4不利于NO2--N的積累;對比2#和3#出水,從NO2--N的積累以及ηTN來看兩者相差不大,3#略好于2#,因此仍選用最佳C/N=8。需要說明的是,如果工程實踐中如果廢水的C/N低于4,應該向廢水補充碳源,但從經(jīng)濟的角度考慮,不宜過多地補充碳源以追求達到C/N=8,到底選用多大的C/N還要綜合技術和經(jīng)濟等因素考慮。
表3 不同C/N下出水水質(zhì)
編號C/NNH3-NNO2--NNO3--NηTNNO2--N/NO3--N1#209.419.770.90.52#4022.63.673.26.33#8019.62.977.56.72.2 運行周期內(nèi)氮元素的跟蹤試驗
根據(jù)0.8L小反應器確定的進水NH3-N100mg/L,COD800mg/L,DO維持0.5~1.0mg/L,pH維持8.0~8.2運行12L大反應器,二周后出水水質(zhì)基本穩(wěn)定后對反應周期內(nèi)對各種形態(tài)氮進行跟蹤,結(jié)果見表4。根據(jù)表4作圖1,并計算出表5反應周期的每1hr時間間隔內(nèi)各種形態(tài)氮的變化量。
表4反應器水質(zhì)跟蹤數(shù)據(jù)
時間(hr)NO2--N(mg/L)NO3--N(mg/L)NH3-N(mg/L)TN(mg/L)ηNH3-N(%)ηCODcr(%)ηTN(%)00.26.35056.500019.63.038.851.461.286.248.6214.53.130.347.969.788.752.1319.53.617.640.782.488.859.3424.85.72.332.897.788.367.2522.99.4 032.310087.067.7618.812.7031.510088.768.5712.116.4028.510089.271.589.617.6027.210090.072.896.216.3022.510090.177.5104.415.9020.310090.679.7
表5 反應周期的每1hr時間間隔內(nèi)各種形態(tài)氮的變化量(mg/L)
時間(hr)NO2--NNO3--NNH3-NTN0~19.4-3.3-11.2-5.11~24.90.1-8.5-3.52~35.00.5-12.7-7.23~45.32.0-15.3-8.04~5-5.95.8-2.3-2.45~6-18.112.00-6.16~7-0.71.000.37~81.5-1.80-0.38~9-1.4-0.60-3.59~101.2-3.10-3.53.結(jié)論
?。?)通過小反應器對比實驗,確定了SBR工藝實現(xiàn)短程硝化反硝化的優(yōu)化條件是pH 8.0~8.2、DO 0.5 mg/L~1.0mg/L,C/N≥4。需要說明的是,與小反應器采用曝氣頭與空壓機結(jié)合曝氣不同,大反應器采用的是曝氣板與大反應器結(jié)合曝氣,由于廢水壓頭有70cm水柱,曝氣量調(diào)節(jié)沒有小反應器方便,以至在反應進行到5hr~6hr后雖然曝氣量沒有改變,但反應器內(nèi)DO卻上升到2mg/L左右,因此由圖1可以看出,這一階段NO3--N的濃度有所上升,超過了NO2--N的水平,這也說明在整個運行周期中DO對NO2--N的積累起到了很大的作用。
(2)對表5進行分析可以得到以下結(jié)論:
?、?hr~7hr,NO3--N的濃度達到了最大值,而6hr~8hr內(nèi)TN幾乎沒有變化。(第7hr的TN為24.5mg/L,而第6hr和第8hr的TN均為24.2mg/L;實際上在沒有外加N源的情況下,反應器內(nèi)TN的水平只有可能保持不變或減少,所以基本可以認為第7hr的TN測定值24.5mg/L屬于實驗誤差)根據(jù)微生物反應動力學規(guī)律,隨著底物濃度C越大,反應速度dC/dt也會增加,而在NO3--N的濃度達到最大之后的一段時間內(nèi)并TN沒有減少,可以判定整個反應過程中不可能由NO3--N直接反硝化脫氮。也就是說NO3--N必須先轉(zhuǎn)化為NO2--N,再由后者實現(xiàn)脫氮。
②在反應的7hr~10hr,NO3--N的濃度相對較大,而這段時間內(nèi)NO3--N轉(zhuǎn)化為NO2--N的量僅為24.4mg/L-18.9mg/L=4.5mg/L,說明說這一反應的速度是很慢的;而0hr~7hr內(nèi)NO3--N的濃度相對較小的情況下轉(zhuǎn)化為NO2--N的量就更少了,由此可以推斷在整個系統(tǒng)內(nèi)以短程硝化反硝化作用為主。也就是說通過pH、DO、C/N等反應條件的控制,在SBR中實現(xiàn)了短程硝化反硝化。
參考文獻:
1.張小玲,彭黨聰,王志盈.短程硝化-反硝化技術經(jīng)濟特性分析.西安建筑科技大學學報(自然科學版)2002,34(3):239~242
2.Bruce E.Rittmann,Perry L.McCarty.環(huán)境生物技術:原理與應用.清華大學出版社,2002(5):470~496
3.李軍,楊秀山,彭永臻.微生物與水處理工程.化學工業(yè)出版社.2002(9):370~405
4.Jetten M S M,Strous M.The anaerobic oxidation of ammonium[J].FEMS microbiology
reviews,1999,22(5):421~437
5.Mulder,A.,van de Graaf,A.A.,Robertson,L.A.and Kuenen,J.G.(1995). Anaerobic ammonium oxidation discovered in a denitrifying fluidized bed reactor ,FEMS Microbiology Ecol.,16,177~184
6.沈耀良,趙丹,黃勇.廢水生物脫氮新技術——氨的厭氧氧化.蘇州城建環(huán)保學院學報,2002,15(1):19~23
- 1大型綜合在建工程施工項目管理辦法(105頁)
- 2建筑工程計算機繪圖教學
- 32015招標采購法律政策知識點:招標投標監(jiān)督體系
- 4淺析橋梁下部結(jié)構(gòu)設計與施工
- 5由矛盾的對立面走向統(tǒng)一——明箱法與暗箱法綜合設計法
- 6一級建造師復習資料:注漿工藝
- 72015年二級建造師《施工管理》知識點(六十五)
- 8花鏡設計與施工56P
- 9陜西某住宅小區(qū)工程現(xiàn)場材料管理實踐(PPT 圖文并茂)
- 10鎮(zhèn)溧高速公路某標段(實施)施工組織設計
- 11招標師專業(yè)考試難度
- 12監(jiān)理工程師答疑精華:風險對項目產(chǎn)生影響的表格
- 132007年二級建造師水工案例精講提綱及內(nèi)容(四)
- 14淺論道路工程中施工單位的質(zhì)量控制
- 15ZQL32/64型連續(xù)梁造橋機總體設計與結(jié)構(gòu)創(chuàng)新
- 16橋梁空心墩身質(zhì)量驗收標準
- 172013年中國智慧城市快速發(fā)展拉動IT需求攀升
- 182015造價工程師:工程設計
- 19鋼結(jié)構(gòu)工程空間結(jié)構(gòu)施工技術介紹(附圖)
- 20學校綠化施工組織設計25p
- 21一級建造師復習資料:工程變更價款確定的程序是什么
- 22淺談瀝青混合料攤鋪機平整度控制
- 23一級建造師市政工程知識點:井點降水
- 24某橋工程菱形掛籃計算書
- 25連續(xù)箱梁預應力鋼筋張拉工施工安全要求
- 26建筑工程施工質(zhì)量管理標準
- 27安全工程師考試《安全生產(chǎn)法》課程講義(2)
- 28懸挑腳手架施工方案
- 29黑龍江某污水處理廠施工組織設計
- 30防水工程質(zhì)量控制措施
成都公司:成都市成華區(qū)建設南路160號1層9號
重慶公司:重慶市江北區(qū)紅旗河溝華創(chuàng)商務大廈18樓