工程項(xiàng)目管理系統(tǒng) | OA系統(tǒng) | ERP系統(tǒng) | 工程項(xiàng)目管理軟件 | 裝飾管理系統(tǒng) | 簽約案例 | 購買價(jià)格 | 在線試用 | 手機(jī)APP | 產(chǎn)品資料
X 關(guān)閉
工程項(xiàng)目管理軟件系統(tǒng)

當(dāng)前位置:工程項(xiàng)目OA系統(tǒng) > 建筑OA系統(tǒng) > 工程項(xiàng)目管理軟件系統(tǒng)

解析燃?xì)夂鏍t火焰檢測不穩(wěn)定改造

申請免費(fèi)試用、咨詢電話:400-8352-114

【摘要】本文是以烘爐燃燒時(shí)火焰檢測設(shè)備的故障全過程為實(shí)例,探討分析影響烘爐火焰檢測穩(wěn)定的各種因素,詳述與之相對應(yīng)的檢修對策及效果,說明通過改進(jìn)修檢工藝,可以有效地提高烘爐滅火保護(hù)裝置的可靠性。 【 abstract 】 this article is based on oven burning flame detection equipment failure process as an example, analyzes factors which influenced the stability of the oven flame detection, detail and the corresponding repair measures and effect, and that by improving the inspection process, can effectively improve the reliability of oven fire protection device.   【關(guān)鍵詞】電離電極;火焰監(jiān)測器;程序控制器;穩(wěn)定性 【 key words 】 the ionization electrode; Flame monitor; Program controller; The stability        1 前言 1 introduction      筆者對廣州某公司在運(yùn)轉(zhuǎn)的三臺烘爐進(jìn)行了半年時(shí)間的觀察及檢測,發(fā)現(xiàn)了因設(shè)計(jì)、安裝質(zhì)量、檢修調(diào)整、燃燒工況(調(diào)整)等諸多問題,爐膛外火焰檢測信號長期不穩(wěn)定,多次出現(xiàn)保護(hù)誤動現(xiàn)象,嚴(yán)重影響了機(jī)組的安全穩(wěn)定運(yùn)行。一方面火檢裝置本身存在不穩(wěn)定因素,另一方面燃燒控制設(shè)備可控性差;燃燒調(diào)整不當(dāng)又反過來影響火檢的穩(wěn)定,并多次影響工作效率,本文就怎樣對烘爐火焰檢測改造進(jìn)行探討。 The author a company working in guangzhou three oven for half a year's observation and testing, found due to the quality of design, installation, maintenance adjustment (adjustment), combustion conditions and so on many issues, outside the furnace flame detection signal is not stable for a long time, multiple occurrences of protection misoperation phenomenon, seriously affecting the safe and stable operation of the unit. Fire detection device itself exists unstable factors on one hand, on the other hand, poor combustion control equipment control; Improper combustion adjustment, in turn, influence the stability of the flame detector, and influence work efficiency many times, this article on how to oven flame detection transformation were discussed.      2 影響火檢穩(wěn)定的因素分析 Two factors affecting the stability of the flame detector is analyzed      從烘爐設(shè)備分析火檢不穩(wěn)定原因應(yīng)從火檢裝置本身和燃燒變化兩個(gè)方面進(jìn)行分析,找出制約火檢光(電)信號傳輸、處理不合理環(huán)節(jié)和燃燒工況變差的因素,并采取有效的檢修對策改進(jìn)設(shè)備、燃燒控制以及改善調(diào)整,完全可以消除鍋爐火檢不穩(wěn)定現(xiàn)象,這在1號、2號爐改造后15個(gè)火檢的良好運(yùn)行工況得到了證明。 From oven equipment this paper analyzes the reasons of unstable flame detector should from the device itself and the combustion flame detector changes two aspects carries on the analysis, find the fire detector (electricity) light signal transmission, processing, unreasonable links and combustion condition, and take effective maintenance measures to improve equipment, combustion control, and improve the adjustment, can completely eliminate the phenomenon of boiler flame detector is not stable, after the reform in boiler no. 1, 2, 15 got prove that fire inspection of good operation condition.   2.1 火焰監(jiān)測器安裝位置不合理。 2.1 the flame monitor installation position is not reasonable.   火焰監(jiān)測器的安裝位置、傾角在導(dǎo)光管中的相對位置兩個(gè)問題。由于燃?xì)馊紵鲾U(kuò)散角、初燃區(qū)范圍大小的差異,所以導(dǎo)光管與燃燒器傾角安裝,并以一定的傾角對準(zhǔn)初燃區(qū)中部靠前處,如果導(dǎo)光管沒對準(zhǔn)初燃區(qū)或者插入困難而沒有伸到位影響視角,都會嚴(yán)重影響檢光效果?;饳z信號偏弱,不能正確反映燃燒的實(shí)際工況,燃燒負(fù)荷較低時(shí),易誤發(fā)無火信號。(圖1) The installation location, Angle of the flame monitor the relative position of two questions in the light pipe. Due to gas burner diffusion Angle, in the early combustion zone size difference, so the light pipe installation with the burner Angle, and aim at a certain Angle in the early combustion zone in central front place, if the light pipe out early combustion zone or insert difficult without stretch in place influence Angle, will seriously affect the light effect. Fire detection signal is weak, can not correctly reflect the actual working condition of the combustion, combustion at low load, easy to mistakenly send no fire signal. (figure 1)   2.2 火焰監(jiān)測器能變差或積灰。 2.2 the flame monitor can worsen or dust.   由于導(dǎo)光管冷卻效果不好而造成導(dǎo)光管前端溫度過高,使導(dǎo)光管過早老化,且探頭維護(hù)不善易積灰,二者都會嚴(yán)重影響通光性能(透光率),使紫外光亮度信號在傳輸過程中大大減弱,從而使火檢信號不穩(wěn)定。 Due to bad cooling effect of the light guide light guide front temperature is too high, make the light guide premature aging, and probe poorly maintained dust easily, both are seriously affecting the optical properties (transmittance) and the ultraviolet luminance signal during transmission greatly reduced, so that the flame detector signal is not stable.   2.3 火焰監(jiān)測器參數(shù)調(diào)整不合理。 2.3 the flame monitor parameter adjustment is not reasonable.   處理好靈敏度和分辨能力兩個(gè)方面的問題,既要有足夠的靈敏度保證火檢信號的穩(wěn)定,又要將本身的火焰同與其相鄰、相對的焰區(qū)分開來。火檢參數(shù)調(diào)整不當(dāng)主要表現(xiàn)在如下方面: Handle both sensitivity and resolution of problems, should not only have enough sensitivity to the stability of the flame monitoring signals of guarantee, and flame with adjacent to itself, apart from the relative flame. Improper parameter adjustment of the flame detector is mainly embodied in the following aspects:   2.3.1 在燃?xì)馊紵墓r下調(diào)整火檢,由于火焰是離燃燒器19.6mm左右向前燃燒,火焰長度是296mm,經(jīng)監(jiān)測后火檢參數(shù)與檢測實(shí)際工況不符。 2.3.1 in gas combustion adjustment under the condition of fire, because fire is around 19.6 mm burner combustion, the flame length is 296 mm, after monitoring the parameters of the flame detector and the detection of actual working condition.   2.3.2 在調(diào)整單臺火檢時(shí)沒有減少給氣量進(jìn)行試驗(yàn)、調(diào)整。 2.3.2 when adjusting a single fire inspection did not decrease for gas testing and adjustment.   2.3.3 中心頻率設(shè)定不準(zhǔn),由于初燃區(qū)火焰閃爍的頻率不僅與煤氣質(zhì)有關(guān),而且與空氣濃度有關(guān),因此中心頻率的設(shè)定宜在60%~70%額定負(fù)荷下進(jìn)行試驗(yàn)、設(shè)定,滿負(fù)荷和最低負(fù)荷下調(diào)整、設(shè)定中心頻率都是不合理的。 2.3.3 center frequency setting is not allowed, because the early combustion zone flame flicker frequency not only related with the gas quality, and is associated with air concentration, so the center frequency of the set should be under 60% ~ 70% rated load test, the setting, full load and the minimum load adjustment, setting the center frequency is not reasonable.   2.3.4 調(diào)整后的火檢參數(shù)沒有進(jìn)行低負(fù)荷、變煤氣質(zhì)(種)的試驗(yàn)和長時(shí)間的考驗(yàn),一旦遇到比試驗(yàn)更差的工況,則可能出現(xiàn)大面積火檢不穩(wěn)而產(chǎn)生保護(hù)誤動。 2.3.4 after adjusting the parameters of the flame detector to low load, the gas mass (kind of) test and the length of the test of time, once encounter less than the test conditions, may appear unstable area fire detection and protection misoperation.   2.3.5 沒有處理好靈敏度和分辨能力之間的矛盾關(guān)系,存在一定的漏檢、誤檢的隱患。 2.3.5 did not deal with the contradiction between the sensitivity and resolving power relations, there is leak and mistakenly identified hazards.   2.4 煤氣量的變化及一次風(fēng)過量。 2.4 the quantity of gas and the wind too much at a time.   煤氣量變差或煤氣熱值降低,則會使煤氣著火距離后移,使初燃區(qū)中心偏離原來火檢導(dǎo)光管對準(zhǔn)的區(qū)域,亮度、頻率會因此而發(fā)生變化,影響火檢信號的穩(wěn)定,同樣風(fēng)機(jī)一次風(fēng)量過大,未燃區(qū)會因一次風(fēng)速增高、煤氣細(xì)度增大而加長,也會使煤氣著火距離后移,典型的情況是鍋爐低負(fù)荷(低于65%額定負(fù)荷)下磨一次風(fēng)量過大,對火檢有明顯影響,這種運(yùn)行工況應(yīng)盡量避免。 Gas quantity difference or gas calorific value is reduced, can make gas ignition distance moved, at the beginning of the combustion zone center deviating from the original light pipe alignment area flame detector, intensity, frequency will change because of this, the stability of the flame monitoring signals of influence, as a fan air volume is too big, not combustion zone due to a higher wind speed and the fineness degree of the gas increases, longer, also can make gas ignition distance backward-shift, typically boiler under low load (less than 65% the rated load) grinding a air volume is too big, had significant effect on the fire inspection, the operation condition should be avoided.   2.5 燃燒控制設(shè)備可靠性差及擺動異常。 2.5 abnormal combustion control equipment reliability is poor and swing.   主要是燃燒器擺角和二次風(fēng)擋板,燃燒器擺角控制異常,部分?jǐn)[到最高、最低,特別是同一層擺角,因噴口燒損變形卡住原因,使擺角出現(xiàn)有的上擺到頂、有的下擺到底的情況,烘爐正常切向燃燒遭到破壞,紫外光導(dǎo)向管跟隨擺動,燃燒器初燃區(qū)火焰仍然偏離檢測區(qū),火焰回流效果差,同時(shí)紫外光在導(dǎo)光管中的位置會因擺動相對后移,使火檢信號偏弱而不穩(wěn),特別是低負(fù)荷更明顯,不但火檢不穩(wěn),還會損壞燃?xì)忾y組。 Mainly swinging Angle of burner and secondary air baffle, the swinging Angle of burner control abnormal, place to the highest and lowest part, especially in the same layer angular, stuck due to the burning of the nozzle deformation reason, make the pendulum Angle appear some on to, in some cases the hem in the end, oven normal tangential combustion destroyed, ultraviolet light pipe run follow swinging, the burner flame combustion zone is still at the beginning of deviating from the detection area, poor flame backflow effect, at the same time uv in the light guide position will due to the relatively backward, make the signal weak and unstable flame detector, especially more obvious under low load, unstable flame detector, not only can damage the gas valve group.   二次風(fēng)擋板開不到位也是嚴(yán)重影響燃燒的因素之一,使燃燒器燃燒配風(fēng)不夠,燃燒工況惡化而使火檢不穩(wěn)。 Secondary air baffle opening does not reach the designated position is one of the serious factors affecting combustion, the combustion burner air distribution is not enough, unstable combustion condition deterioration and make the fire inspection. 3 改造方案 3 retrofit scheme      3.1 要改用電離電極重新定位。 3.1 to convert the ionization electrode repositioning.   電離電極安裝在噴口前方的火焰口內(nèi),火焰要與電極要相互垂直安裝。威索公司根據(jù)燃燒器的尺寸、噴口擴(kuò)散角、額定工況一次風(fēng)速和燃?xì)鈮毫?空氣壓力,燃?xì)鈾z漏確定了火焰的長度為傾角為60°左右,并向前燃燒300mm長火焰,而電離電極要與火焰穩(wěn)焰器垂直并相距20mm。還要做好絕緣和防高溫處理和降溫處理(圖2) Ionization electrode is installed in the flame inside the mouth in front of the nozzle, the flame with electrodes perpendicular to install. Weishaupt company according to the size of the burner, nozzle Angle, the rated working condition of a gas pressure, wind speed and air pressure, gas leak detection to determine the length of the flame inclination to 60 °, and 300 mm long flame combustion, and ionization electrode and the flame stabilizing vertical flame device and 20 mm apart. For insulation and heat treatment and cooling (figure 2)         3.2 改造后的工作過程。 3.2 after transforming the work process.   烘爐的燃燒是由程序控制器LFL1.333給予一定吹掃時(shí)間,并點(diǎn)火在3秒鐘內(nèi)對火焰檢測電離電極是否有導(dǎo)通電流30~50uA返回程序控制器分析如有30-50uA通過則燃燒器繼續(xù)燃燒,否則熄火和報(bào)警,火焰要燃燒充分并有良好藍(lán)色和白紅色的火焰,這樣才能保護(hù)好電離電極不會結(jié)垢而不能正常狀態(tài)工作。 Oven combustion is a program controller LFL1.333 offer certain purging time and ignition of flame ionization detection within 3 seconds if there is a drive electrode current 30 ~ 50 ua return analysis if there is a 30-50 ua program controller through the burner to burn, or shut down and alarm, fire will burn sufficiently and blue and white and red flame is good, in this way can we protect the ionization electrode will not scale and can't normal work.   3.3 兩臺爐目前火檢設(shè)備改造前后對比。 3.3 two furnace fire inspection comparison before and after the equipment reform at present.   電離電極檢測是只要有火焰燃燒就有電流通過,并能安全保護(hù)整套設(shè)備正常狀態(tài)工作。 Ionization electrode detection is as long as the flame is the current through, and the set safety protection equipment normal work.   火焰監(jiān)測器檢測不能有效檢測火焰如導(dǎo)光管有灰和不反光,還有其它光線的干擾和誤動作還有火焰燃燒不穩(wěn)定而做成不能正常工作對火檢設(shè)備進(jìn)行長達(dá)一年的對比后,兩臺爐共有15個(gè)火檢,設(shè)備本身缺陷已完全消除,火檢裝置的參數(shù)改造已全面完善,能比較真實(shí)地反映烘爐單個(gè)燃燒器的燃燒工況,終于實(shí)現(xiàn)兩臺爐火檢設(shè)備缺陷“0”目標(biāo)。 Flame monitor tests are not effective flame detection such as light pipe is grey and not reflective, and other light interference and false action and flame instability and make it can't work normally fire inspection equipment for up to one year after contrast, a total of 15 fire inspection two furnace, the equipment itself defect has been completely eliminated, the parameters of the flame monitoring device has a comprehensive, can more truly reflect the oven single burner combustion condition, finally realize the two fire detection equipment defects "zero" goal.   3.4 烘爐改造后火檢效益。 3.4 oven after transforming the fire inspection efficiency.   2007年5月~2008年5月,1號、2號機(jī)火檢誤動僅0次,已大大降低誤動作,還能提高生產(chǎn)效率,提高工作質(zhì)量。 In May 2007 to May 2008, no. 1, no. 2 machine maloperation of the flame detector is only 0 times, has greatly reduce misoperation, it can improve the production efficiency, improve the quality of work.   通過火檢綜合測檢,調(diào)試后一年沒有發(fā)生過烘爐滅火保護(hù)誤動,工作一年內(nèi)沒有發(fā)生保護(hù)誤動而造成停產(chǎn),滅火保護(hù)裝置的可靠性明顯提高。烘爐運(yùn)行良好的工作狀態(tài),充分體現(xiàn)了其在技術(shù)改良后的穩(wěn)定性,確保了生產(chǎn)效率及工作質(zhì)量的提高。 By fire inspection comprehensive measurement inspection, debugging after one year there have been no oven fire protection maloperation, working within a year of protection misoperation caused production does not occur, the reliability of the fire protection system has improved significantly. Oven running in good working condition, fully embodies the its stability after technical improvement, to ensure the production efficiency and improve the quality of our work.
發(fā)布:2007-07-28 12:47    編輯:泛普軟件 · xiaona    [打印此頁]    [關(guān)閉]
相關(guān)文章:

泛普工程項(xiàng)目管理軟件系統(tǒng)其他應(yīng)用

項(xiàng)目管理工具 禪道項(xiàng)目管理軟件 夢龍項(xiàng)目管理軟件 微軟項(xiàng)目管理軟件 裝飾管理系統(tǒng) 裝修預(yù)算軟件 項(xiàng)目計(jì)劃軟件 項(xiàng)目進(jìn)度管理軟件 軟件項(xiàng)目管理工具 材料管理軟件 工程項(xiàng)目管理軟件系統(tǒng) 項(xiàng)目管理系統(tǒng) 施工管理軟件 建筑工程項(xiàng)目管理軟件 工程管理軟件